Panodyne COVID-19 Antigen & Flu Combo Rapid Test Kit. Box of 24

£280.00

The unique COVID-19 and flu A/B Antigen test kit can help combat the spread of COVID-19 and the winter Influenza flu virus with early detection.

  • Precise, reliable and accurate
  • Easy to use and read results
  • Suitable for massive scale testing

Documentation

4 in stock (can be backordered)

Description

Panodyne COVID-19 Antigen & Flu Combo Rapid Test Kit. Box of 24

The unique COVID-19 and flu A/B Antigen test kit can help combat the spread of COVID-19 and the winter Influenza flu virus with early detection.

• Results ready in 15 minutes
• Accurate diagnostic tool for active infection
• Easy to administer and read results
• Affordable, no need for instrument, highly portable
• Enable testing on a massive scale
• For healthcare workers use only

COVID-19 & FLU A/B Antigen Test Kit (Colloidal Gold) is used for in vitro qualitative detection of 2019 Novel Coronavirus antigen and influenza A/B antigen in human nasopharyngeal swab samples.


INTRODUCTION

With the COVID-19 pandemic still on an upward trend in much of the United Kingdom, flu season looks different this year. “Double whammy” and “twindemic” have been used to describe the tsunami of the two respiratory viruses.

However, if you do come down with symptoms of cough, fever, and body aches, there is now a one-step Influenza antigen rapid test cassette available that can determine whether it is COVID-19, influenza, or neither one. The new test can quickly arrive at the cause of your sickness to help you get the treatment you need ASAP. Just like the Coronavirus swab test, which goes high up into your nasal passage to collect samples, the new Panodyne SARS-CoV-2/FluA/FluB antigen test is performed the same way.

Both COVID-19 and influenza A/B viruses (Flu A/B) can cause acute respiratory infections, and people are generally susceptible. These three viruses are highly contagious, spread quickly, have a short incubation period, and have a high incidence. Symptoms of COVID-19 and influenza may look similar, the main symptoms include:

  • Fever 
  • Dry Cough
  • Fatigue

With this combination test, healthcare workers can provide an accurate diagnosis to patients and treat them with the appropriate measures.

MATERIALS SUPPLIED

• Sampling swab (nasopharyngeal swab)
• Antigen extraction buffer
• Antigen extraction tube and dropper tip
• Paper workbench for 24 test kits (The one-test-box can be used as a workbench)
• Instruction for use
• Test kit

FOR COVID-19 ANTIGEN TEST KIT:

NEGATIVE: If only the C band is present, the absence of any burgundy color in the T band indicates that no COVID-19 antigen is detected in the specimen. The result is negative.

POSITIVE: In addition to the presence of C band, if T band is developed, the test indicates for the presence of COVID-19 antigen in the specimen. The result is COVID-19 positive.

INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and
repeat the test with a new test cassette. If the problem persists, discontinue using the test kit immediately and contact your local distributor

FOR FLU A/B ANTIGEN TEST KIT:

NEGATIVE: If only the C band is present, the absence of any burgundy color in the T band indicates that no Flu NB antigen is detected in the specimen. The result is negative.

POSITIVE

FLU A/B positive: In addition to the presence of the C-line, If the test lines A and B appears at the same time, it means that there are both influenza A virus antigen and influenza B virus antigen
in the sample, that is, the result is positive for FLU A and FLU B.

FLU A positive: In addition to the presence of the C-line, if the test line A appears, the test indicates the presence of FLU A antigen in the sample, that is, the result is positive for FLU A

FLU B positive: In addition to the presence of the C-line, if the test line B appears, the test indicates the presence of FLU B antigen in the sample, that is, the result is positive for FLU B.

INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and
repeat the test with a new test cassette. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

Additional information

Brand

Manufacturer

Qualitative/Quantitative

Qualitative

Sample Volume

3 Drops of Extracted Solution (about 100µl) Each Well

Sample Type

Nasopharyngeal Swab

Test Principle

Colloidal Gold Method

Test Time

15 Mins

Shelf Life

2 years

Reviews

There are no reviews yet.

Be the first to review “Panodyne COVID-19 Antigen & Flu Combo Rapid Test Kit. Box of 24”

FAQs

What are the storage requirements?

The test kit can be stored at room temperature or refrigerated (2-30°C). The test
device is stable through the expiration date printed on the sealed pouch. The test
device must remain in the sealed pouch until use.
• Do not freeze.
• Do not use beyond the expiration date.
• After opening the sealed pouch, use the test as soon as possible within 60 minutes

SPECIMEN COLLECTION

1. SARS-CoV-2/FluA/FluB Antigen Test kit (Colloidal Gold) can be
performed using nasopharyngeal swab.
2. Testing should be performed immediately after specimen collection.
3. Bring specimens to room temperature prior to testing.
4. If specimens are to be shipped, they should be packed in compliance with local
regulations covering the transportation of etiologic agents.